  • Sale

    Fluke 1587 FC - Multímetro de Aislamiento 2 en 1 con Connect

    Fluke 1587 FC - Multímetro de Aislamiento 2 en 1 con Connect

    Megóhmetro de verdadero valor eficaz/probador de resistencia de aislamiento y multímetro con compatibilidad con Fluke Connect

    El DMM de aislamiento 2 en 1 de alto rendimiento.
    El Fluke 1587 FC combinado con Fluke Connect es un probador de aislamiento digital con un multímetro digital de verdadero valor eficaz con todas las funciones en una única unidad portátil compacta, que proporciona la máxima versatilidad tanto para la resolución de problemas como para el mantenimiento preventivo.

    • Tensión CA/CC, milivoltios CC, miliamperios CA/CC, resistencia, continuidad
    • Tensiones de prueba de aislamiento: 50 V, 100 V, 250 V, 500 V, 1000 V
    • Prueba de aislamiento: 0,01 MΩ a 2 GΩ
    • Pantalla grande con retroiluminación

    1587 FC + Fluke Connect®:

    El multímetro de aislamiento Fluke 1587 FC agrega cuatro nuevas y potentes funciones de diagnóstico a través de la aplicación de mediciones Fluke Connect®:

    • Seguridad primero. Manténgase fuera de peligro monitoreando las mediciones de sus pruebas de forma remota.
    • Demuestre que su trabajo se realizó correctamente viendo y compartiendo rápidamente los resultados de las mediciones de forma inalámbrica con su teléfono inteligente.
    • Encuentre problemas rápidamente guardando y comparando mediciones a lo largo del tiempo en un dispositivo inalámbrico.
    • El seguimiento histórico y las tendencias de los activos identifican la degradación a lo largo del tiempo y permiten tomar decisiones en tiempo real sobre el terreno con Fluke Connect® Assets (se vende por separado).
    Maximum voltage applied to any terminal and common 1000 V
    Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
    Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
    Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
    Relative humidity Noncondensing
    0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
    0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
    0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
    Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
    Radio frequency communication 2.4 GHz ISM Band
    Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
    Electromagnetic compatibility
    International IEC 61326-1 Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A : Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.

    Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
    Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Enclosure protection IEC 60529: IP40 (non-operating)
    Safety IEC 61010-1 Pollution Degree 2
    IEC 61010-2-033 CAT IV 600 V/CAT III 1000 V
    Batteries Four AA batteries (NEDA 15A or IEC LR6)
    Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off.
    Size 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
    Weight 550 g (1.2 lb)
    Altitude Operating 2000 m
    Storage 12,000 m
    Over-Range capability 110 % of range except for capacitance which is 100 %
    Frequency overload protection <107 V-Hz
    Fuse Protection for mA input 0.44A, 1000 V, IR 10 kA
    AC voltage measurement
    Accuracy (1587 FC only)
    Range Resolution 50 Hz to 60 Hz ± (% of Rdg + counts) 60 Hz to 5000 Hz ± (% of Rdg + counts)
    600.0 mV 0.1 mV ± (1 % + 3) ± (2 % + 3)
    6.000 V 0.001 V ± (1 % + 3) ± (2 % + 3)
    60.00 V 0.01 V ± (1 % + 3) ± (2 % + 3)
    600.0 V 0.1 V ± (1 % + 3) ± (2 % + 3) 1
    1000 V 1 V ± (2 % + 3) ± (2 % + 3) 1
    1 1 kHz bandwidth
    Low-Pass Filter Voltage (1587 FC only)
    Range Resolution 50 Hz to 60 Hz ± (% of Rdg + Counts) 60 Hz to 400 Hz ± (% of Rdg + Counts)
    600.0 mV 0.1 mV ± (1 % + 3) + (2 % + 3) - (6 % - 3)
    6.000 V 0.001 V ± (1 % + 3) + (2 % + 3) - (6 % - 3)
    60.00 V 0.01 V ± (1 % + 3) + (2 % + 3) - (6 % - 3)
    600.0 V 0.1 V ± (1 % + 3) + (2 % + 3) - (6 % - 3)
    1000 V 1 V ± (2 % + 3) + (2 % + 3) - (6 % - 3)
    1577 accuracy
    Range Resolution 50 Hz to 60 Hz ± (% of Rdg + Counts)
    600.0 mV 0.1 mV ± (2 % + 3)
    6.000 V 0.001 V ± (2 % + 3)
    60.00 V 0.01 V ± (2 % + 3)
    600.0 V 0.1 V ± (2 % + 3)
    1000 V 1 V ± (2 % + 3)
    AC Conversion Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to a crest factor =1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3.
    Input Impedance 10 MΩ (nominal), <100 pF, ac-coupled
    Common mode rejection ratio (1 kΩ unbalanced) >60 dB at dc, 50 or 60 Hz
    DC voltage measurement
    Range Resolution Accuracy 1587 FC1
    ± (% of Rdg + Counts)
    Accuracy 15771
    ± (% of Rdg + Counts)
    6.000 V dc 0.001 V ± (0.09 % + 2) ± (0.2 % + 2)
    60.00 V dc 0.01 V ± (0.09 % + 2) ± (0.2 % + 2)
    600.0 V dc 0.1 V ± (0.09 % + 2) ± (0.2 % + 2)
    1000 V dc 1 V ± (0.09 % + 2) ± (0.2 % + 2)
    1 Accuracies apply to ± 100% of range.
    Input Impedance: 10 MΩ (nominal), <100 pF
    Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz
    Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalanced)
    DC millivolts measurement
    Range Resolution Accuracy 1587 FC ± (% of Rdg + Counts) Accuracy 1577 ± (% of Rdg + Counts)
    600.0 mV dc 0.1 mV ± (0.1 % + 1) ± (0.2 % + 1)
    DC and AC current measurement
    Range Resolution Accuracy 1587 FC ± (% of Rdg+Counts) Accuracy 1577 ± (% of Rdg+Counts) Burden voltage (Typical)
    AC 45 Hz to 1000 Hz 400 mA 0.1 mA ± (1.5 % + 2) 1 ± (2 % + 2) 1 2 mV/mA
    60 mA 0.01 mA ± (1.5 % + 2) 1 ± (2 % + 2) 1  
    DC 400 mA 0.1 mA ± (0.2 % + 2) ± (1.0 % + 2) 2 mV/mA
    60 mA 0.01 mA ± (0.2 % + 2) ± (1.0 % + 2)  
    1 1 kHz bandwidth
    Overload: 600 mA for 2 minutes maximum
    Fuse protection for mA Input: 0.44 mA, 1000 V, IR 10 kA
    AC conversion: Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor =1.5 at 600 mA. For non-sinusoidal waveforms add +(2 % reading + 2 % FS) typical, for a crest factor up to 3.
    Ohms measurement
    Range Resolution Accuracy 1587 FC1
    + (% of Rdg+Counts)
    Accuracy 15771
    + (% of Rdg+Counts)
    600.0 Ω 0.1 Ω ± (0.9 % + 2) ± (1.2 % + 2)
    6.000 kΩ 0.001 kΩ
    60.00 kΩ 0.01 kΩ
    600.0 kΩ 0.1 KΩ
    6.000 MΩ 0.001 MΩ
    50.0 MΩ [2] 0.01 MΩ ± (1.5 % + 3) ± (2.0 % + 3)
    1 Accuracies apply from 0 % to 100 % of range. 2 Up to 80 % relative humidity.
    Overload protection: 1000 V rms or dc
    Open circuit test voltage: <8.0 V dc
    Short circuit current: <1.1 mA
    Diode test (1587 FC only)
    Diode test indication Display voltage drop: 0.6 V at 1.0 mA nominal test current
    Accuracy ± (2 % + 3)
    Continuity test
    Continuity indication Continuous audible tone for test resistance below 25 O and off above 100 O. Maximum reading; 1000 O
    Open circuit voltage <8.0 V
    Short circuit current 1.0 mA typical
    Overload protection 1000 V rms
    Response time >1 m sec
    Frequency measurement (1587 FC only)
    Range Resolution Accuracy ± (% of Rdg+Counts)
    99.99 Hz 0.01 Hz ± (0.1 % + 1)
    999.9 Hz 0.1 Hz ± (0.1 % + 1)
    9.999 kHz 0.001 kHz ± (0.1 % + 1)
    99.99kHz 0.01 kHz ± (0.1 % + 1)
    Frequency counter sensitivity
    Input range V ac Sensitivity (RMS Sine Wave)1 DC trigger levels to 20 kHz2
    5 Hz to 20 kHz 20 kHz to 100 kHz  
    600.0 mV ac 100.0 mV 150.0 mV NA
    6.0 V 1.0 V 1.5 V -400.0 mV and 2.5 V
    60.0 V 10.0 V 36.0 V 1.2 V and 4.0 V
    600.0 V 100.0 V   12.0 V and 40.0 V
    1000.0 V 300.0 V   12.0 V and 40.0 V
    1 Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy.
    2 Usable to 100 kHz with full scale input.
    Capacitance (1587 FC only)
    Range Resolution Accuracy ± (% of Rdg+Counts)
    1000 nF 1 nF ± (1.2 % + 2)
    10.00 µF 0.01 µF
    100.0 µF 0.1 µF ± (1.2 % + 90 counts)
    9999 µF 1 µF
    Temperature measurement (1587 FC only)
    Range Resolution Accuracy 1 ± (% of Rdg+Counts)
    -40 ° C to 537 ° C 0.1 °C ± (1 % + 10 counts)
    -40 ° F to 998 ° F 0.1 °F ± (1 % + 18 counts)

    1 Las precisiones se aplican después de un tiempo de estabilización de 90 minutos después de un cambio en la temperatura ambiente del instrumento.

    Measurement range Model 1587 FC: 0.01 MΩ to 2 GΩ
    Model 1577: 0.1 MΩ to 600 MΩ
    Test voltages Model 1587 FC: 50, 100, 250, 500, 1000 V
    Model 1577: 500, 1000 V
    Test voltage accuracy +20 %, -0 %
    Short-Circuit test current 1 mA nominal
    Auto discharge Discharge time <0.5 second for C = 1 µF or less
    Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
    Maximum capacitive load Operable with up to 1 µF load

    Plantilla multímetros

      • Estilo: De mano
      • Medidas AC V: Sí
      • Medidas DC V: Sí
      • Medidas AC A: Sí
      • Medidas DC A: Sí
      • RMS verdadero: Sí
      • Tensión máxima A: 1000 V
      • Resolución Voltios CA: 0,1 V (100 mV)
      • Voltaje máximo CC: 1000 V
      • Resolución Voltios CC: 0,001 V (1 mV)
      • Corriente máxima CA: 400 mA (0,4 A)
      • Corriente mínima CA: 1 mA
      • Resolución Corriente CA: 0,01 mA
      • Corriente máxima CC: 400 mA (0,4 A)
      • Corriente mínima CC: 1 mA
      • Resolución Corriente CC: 0,01 mA
      • Precisión básica V CC: ±(0,09%+2)
      • # Pantalla de dígitos: 3,75
      • Cuentas: 6000.
      • Luz de fondo: Sí
      • Manual/Autorango: Ambos
      • Decibeles: No
      • Resistencia: Sí
      • Frecuencia: Sí
      • Capacitancia: Sí
      • Temperatura: Sí
      • Prueba de diodo: Sí
      • Clasificación CAT: IV
      • Voltaje CAT: 1000 V, 600 V
      • Intrínsecamente seguro: No
      • Retención de picos: Sí
      • Protector de sobrecarga: Sí
      • Capacidad de medición Kelvin de 4 cables: No
      • Pantalla inalámbrica: No
      • Retención de datos: Sí
      • Filtro de paso bajo: Sí

      Plantilla de probadores de resistencia de aislamiento Micro / Milli / Meg Ohmímetros / Megóhmetros

      • Voltaje de prueba de infrarrojos: 1000 V, 100 V, 250 V, 50 V, 500 V
      • Resistencia máxima de aislamiento: 2 G ohmios
      • Tipo: Batería
      • Resistencia mínima de aislamiento: 0,01 M ohmios (0,00001 G ohmios)
      • Voltaje incremental variable: No
      • Pantalla (Megóhmetro): Digital
      • Prueba de continuidad: Sí
      • Detección de voltaje de circuito vivo: Sí
      • Fuente de alimentación: batería
      • Temporizador: Sí

      Atributos generales del equipo de prueba

        • Garantía: 3 años
        • Aprobación de seguridad: CSA
        • Clasificación IP: IP40
        • Peso del producto: 4,72 libras
        • Altura del producto: 7,99 pulgadas
        • Longitud del producto: 3.97 PULGADAS
        • Ancho del producto: 7,96 PULGADAS
        • Registro de datos: No
        • Calibración incluida: ninguna
        • Tipo de batería: AA
        • Voltaje de fuente de alimentación: alimentado por batería.
        • País de origen: Estados Unidos
        • UPC: 095969262958

        Customer Reviews

        Be the first to write a review
        0%
        (0)
        0%
        (0)
        0%
        (0)
        0%
        (0)
        0%
        (0)